pump design:
positive displacement three chamber diaphragm pump
general water delivery
motor:
permanent magnet
voltage:
24vac
material:
plastics - nylon
valves - EPDM
diaphragm - santoprene
control:
adjustable switch - shut-off 90psi +/- 10psi
restart 30psi +/- 5psi
liquid temperature:
60 ºC (140 ºF) max
self-prime:
yes, up to 2 meters
runs dry without damage
ports:
3/8in - 1/8in FNPT
net weight:
1.93kg
duty cycle:
continuous
Inlet: 0psi (self-priming)
open flow |
0.97 |
0.24 |
10 |
0.96 |
0.27 |
20 |
0.89 |
0.31 |
30 |
0.87 |
0.37 |
40 |
0.85 |
0.42 |
50 |
0.80 |
0.48 |
60 |
0.75 |
0.54 |
70 |
0.69 |
0.59 |
80 |
0.63 |
0.63 |
90 |
0.54 |
0.67 |
All data based on testing with water
Voltage (volts): 24V AC/DC / 1.24A / Adapter
Note: Performance will vary with variation in service voltage and transformer output.